Model No.︰GH-1,GH-2
Brand Name︰GIGAVAC
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc
GH1 No Load Switching
Low, stable contact resistance minimizes loss in RF circuits
High carry current, 25Adc continuous, in a small package
GH3 Make & Break Load Switching
Durable tungsten contacts for hot load switching
Vacuum dielectric for effective arc quenching when opening under load
GH5 Make Only Load Switching
Excellent for capacitive discharge and safety dump switch applications
Additional isolation capabilities in many applications
Contact & Relay Ratings |
Units |
GH1 |
GH3 |
GH5 |
|
Contact Form |
|
C |
C |
C |
|
Contact Arrangement |
|
SPDT |
SPDT |
SPDT |
|
Test Voltag,(kV, Peak), Test Max., Contacts & to Base (15 uA Leakage Max., dc or 60Hz) |
KV Peak |
5 |
5 |
5 |
|
Rated Operating Voltage,(kV,Peak), Contacts & to Base (15 uA Leakage Max.) |
dc or 60Hz |
KV Peak |
3.5 |
3.5 |
3.5 |
2.5MHz |
Kv Peak |
2.5 |
- |
- |
|
16MHz |
KV Peak |
2 |
- |
- |
|
32MHz |
KV Peak |
1.5 |
- |
- |
|
Continuous Current, Carry Max |
dc or 60Hz |
Amps |
25 |
18 |
8 |
2.5MHz |
Amps |
14 |
- |
- |
|
16MHz |
Amps |
9 |
- |
- |
|
32MHz |
Amps |
7 |
- |
- |
|
Coil Hi-Pot (V RMS, 60 Hz) |
V |
500 |
500 |
500 |
|
Capacitance |
Across Open Contacts |
pF |
2 |
- |
- |
Contacts to Ground |
pF |
2.5 |
- |
- |
|
Resistance, Contact Max @ 1A, 28Vdc |
ohms |
0.01 |
0.02 |
0.50 |
|
Operate Time, Max |
ms |
6 |
6 |
6 |
|
Release Time, Max |
ms |
6 |
6 |
6 |
|
Mechanical Life |
Cycles |
2 million |
2 million |
2 million |
|
Weight |
g(02) |
28(1) |
28(1) |
28(1) |
|
Vibration, Sine (10-2000 Hz Peak) |
G's |
10 |
10 |
10 |
|
Shock, 1/2 Sine11ms (Peak) |
G's |
50 |
50 |
50 |
|
Operating Temperature Ambient |
˚C |
-55 ~ +125 |
-55 ~ +125 |
-55 ~ +125 |
Coil Ratings
Nominal, Volts dc |
12 |
26.5 |
115 |
Pick-up, Volts dc, Max |
8 |
16 |
80 |
Drop-Out, Volts dc |
.5-5 |
1-10 |
5-50 |
Coil Resistance(Ω+-10%) |
80 |
330 |
6000 |